  • B210LSHGDZ2MR

    B210LSHGDZ2MR

    INSULATED CASE TYPE; CSA APPROVAL; 1000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES SHORT TIME SELECTIVE INTERLOCK,...

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B210LSHGDZ2PMR

    B210LSHGDZ2PMR

    INSULATED CASE TYPE; CSA APPROVAL; 1000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES SHORT TIME SELECTIVE INTERLOCK,...

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B210LSHGDZ2PR

    B210LSHGDZ2PR

    INSULATED CASE TYPE; CSA APPROVAL; 1000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES SHORT TIME SELECTIVE INTERLOCK,...

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B210LSHGDZ2R

    B210LSHGDZ2R

    CSA APPROVAL; 1000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES SHORT TIME SELECTIVE INTERLOCK

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B210LSHGMR

    B210LSHGMR

    INSULATED CASE TYPE; UL, CSA APPROVAL; 1000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES METERING AND COMMUNICATION

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B210LSHGPMR

    B210LSHGPMR

    INSULATED CASE TYPE; UL, CSA APPROVAL; 1000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES PROTECTIVE RELAY, METERING AND COMMUNICATION

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B210LSHGPR

    B210LSHGPR

    INSULATED CASE TYPE; UL, CSA APPROVAL; 1000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES PROTECTIVE RELAY AND COMMUNICATION

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B210LSHGR

    B210LSHGR

    UL, CSA APPROVAL; 1000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B210LSHGZ1MR

    B210LSHGZ1MR

    INSULATED CASE TYPE; UL, CSA APPROVAL; 1000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES ZONE SELECTIVE INTERLOCK, METERING AND...

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B210LSHGZ1PMR

    B210LSHGZ1PMR

    INSULATED CASE TYPE; UL, CSA APPROVAL; 1000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES ZONE SELECTIVE INTERLOCK, PROTECTIVE RELAY,...

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B210LSHGZ1PR

    B210LSHGZ1PR

    INSULATED CASE TYPE; UL, CSA APPROVAL; 1000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES ZONE SELECTIVE INTERLOCK, PROTECTIVE RELAY AND...

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B210LSHGZ1R

    B210LSHGZ1R

    UL, CSA APPROVAL; 1000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES ZONE SELECTIVE INTERLOCK

    Trip Functions: LSIG
    Family: MicroVersaTrip