Accessories and Parts

  • A216LIGZ1

    A216LIGZ1

    General Electric A216LIGZ1, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 2000A Maximum Allowable CT, 1600A Breaker Current Sensor, Overcurrent Protection: Long-Time, Instantaneous, Ground Fault, Zone-selective Interlock: Ground Fault Only

    Amperage: 1600
    Family: MicroVersaTrip
  • A216LIGZ1M

    A216LIGZ1M

    General Electric A216LIGZ1M, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 2000A Maximum Allowable CT, 1600A Breaker Current Sensor, Overcurrent Protection: Long-Time, Instantaneous, Ground Fault, Zone-selective Interlock: Ground Fault Only, With...

    Amperage: 1600
    Family: MicroVersaTrip
  • A216LIGZ1PM

    A216LIGZ1PM

    General Electric A216LIGZ1PM, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 2000A Maximum Allowable CT, 1600A Breaker Current Sensor, Overcurrent Protection: Long-Time, Instantaneous, Ground Fault, Zone-selective Interlock: Ground Fault Only, With...

    Amperage: 1600
    Family: MicroVersaTrip
  • A216LIM

    A216LIM

    General Electric A216LIM, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 2000A Maximum Allowable CT, 1600A Breaker Current Sensor, Overcurrent Protection: Long-Time, Instantaneous, With Metering and Communication

    Amperage: 1600
    Family: MicroVersaTrip
  • A216LIPM

    A216LIPM

    General Electric A216LIPM, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 2000A Maximum Allowable CT, 1600A Breaker Current Sensor, Overcurrent Protection: Long-Time, Instantaneous, With Metering, Relaying, and Communication

    Amperage: 1600
    Family: MicroVersaTrip
  • A216LSH

    A216LSH

    General Electric A216LSH, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 2000A Maximum Allowable CT, 1600A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Fixed High-range Instantaneous

    Amperage: 1600
    Family: MicroVersaTrip
  • A216LSHG

    A216LSHG

    General Electric A216LSHG, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 2000A Maximum Allowable CT, 1600A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Fixed High-range Instantaneous, Ground Fault

    Amperage: 1600
    Family: MicroVersaTrip
  • A216LSHGZ1

    A216LSHGZ1

    General Electric A216LSHGZ1, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 2000A Maximum Allowable CT, 1600A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Fixed High-range Instantaneous, Ground Fault, Zone-selective...

    Amperage: 1600
    Family: MicroVersaTrip
  • A216LSHGZ2

    A216LSHGZ2

    General Electric A216LSHGZ2, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 2000A Maximum Allowable CT, 1600A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Fixed High-range Instantaneous, Ground Fault, Zone-selective...

    Amperage: 1600
    Family: MicroVersaTrip
  • A216LSI

    A216LSI

    General Electric A216LSI, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 2000A Maximum Allowable CT, 1600A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Instantaneous

    Amperage: 1600
    Family: MicroVersaTrip
  • A216LSIG A216LSIG, front

    A216LSIG

    General Electric A216LSIG, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 2000A Maximum Allowable CT, 1600A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Instantaneous, Ground Fault

    Amperage: 1600
    Trip Functions: LSIG
    Family: MicroVersaTrip
  • A216LSIGM

    A216LSIGM

    General Electric A216LSIGM, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 2000A Maximum Allowable CT, 1600A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Instantaneous, Ground Fault, With Metering and Communication

    Amperage: 1600
    Family: MicroVersaTrip