  • A440LIGZ1

    A440LIGZ1

    General Electric A440LIGZ1, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Instantaneous, Ground Fault, Zone-selective Interlock: Ground Fault Only

    Amperage: 4000
    Family: MicroVersaTrip
  • A440LIGZ1M

    A440LIGZ1M

    General Electric A440LIGZ1M, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Instantaneous, Ground Fault, Zone-selective Interlock: Ground Fault Only, With...

    Amperage: 4000
    Family: MicroVersaTrip
  • A440LIGZ1PM

    A440LIGZ1PM

    General Electric A440LIGZ1PM, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Instantaneous, Ground Fault, Zone-selective Interlock: Ground Fault Only, With...

    Amperage: 4000
    Family: MicroVersaTrip
  • A440LIM

    A440LIM

    General Electric A440LIM, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Instantaneous, With Metering and Communication

    Amperage: 4000
    Family: MicroVersaTrip
  • A440LIPM

    A440LIPM

    General Electric A440LIPM, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Instantaneous, With Metering, Relaying, and Communication

    Amperage: 4000
    Family: MicroVersaTrip
  • A440LSGZ2M A440LSGZ2M, front

    A440LSGZ2M

    General Electric A440LSGZ2M, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Ground Fault, Zone-selective Interlock: Ground Fault and...

    Amperage: 4000
    Family: MicroVersaTrip
  • A440LSH

    A440LSH

    General Electric A440LSH, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Fixed High-range Instantaneous

    Amperage: 4000
    Family: MicroVersaTrip
  • A440LSHG

    A440LSHG

    General Electric A440LSHG, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Fixed High-range Instantaneous, Ground Fault

    Amperage: 4000
    Family: MicroVersaTrip
  • A440LSHGZ1

    A440LSHGZ1

    General Electric A440LSHGZ1, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Fixed High-range Instantaneous, Ground Fault, Zone-selective...

    Amperage: 4000
    Family: MicroVersaTrip
  • A440LSHGZ2

    A440LSHGZ2

    General Electric A440LSHGZ2, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Fixed High-range Instantaneous, Ground Fault, Zone-selective...

    Amperage: 4000
    Family: MicroVersaTrip
  • A440LSI

    A440LSI

    General Electric A440LSI, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Instantaneous

    Amperage: 4000
    Family: MicroVersaTrip
  • A440LSIG

    A440LSIG

    General Electric A440LSIG, MicroVersaTrip, Trip Unit, Used On AKR Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Instantaneous, Ground Fault

    Amperage: 4000