General Electric

  • TKUV10R

    TKUV10R

    DC TYPE; TB6/TBC6/TB8/TBC8/THKM/TKC/TKM SERIES MOLDED CASE CIRCUIT BREAKER USED ON; 125 V DC VOLTAGE RATING; RIGHT POLE MOUNTING LOCATION; FIELD INSTALLED; NOMINAL CURRENT RATING 18 MILLIAMPERE

    Family: K1200 Line
  • TKMASTA9L

    TKMASTA9L

    REMOTE TYPE; TB6/TB8/TBC6/TBC8/THKM/TKC/TKM SERIES CIRCUIT BREAKER USED ON; 48 V DC VOLTAGE RATING; LEFT POLE MOUNTING LOCATION; FIELD INSTALLED; INRUSH CURRENT 2.4 AMPERE (DC); TKMASTA MODEL

    Family: K1200 Line
  • TKMASTA8R

    TKMASTA8R

    REMOTE TYPE; TB6/TB8/TBC6/TBC8/THKM/TKC/TKM SERIES CIRCUIT BREAKER USED ON; 24 V DC VOLTAGE RATING; RIGHT POLE MOUNTING LOCATION; FIELD INSTALLED; INRUSH CURRENT 4.6 AMPERE (DC); TKMASTA MODEL

    Family: K1200 Line
  • TKMASTA12R

    TKMASTA12R

    REMOTE TYPE; TB6/TB8/TBC6/TBC8/THKM/TKC/TKM SERIES CIRCUIT BREAKER USED ON; 50/60 HZ FREQUENCY RATING; 120/240 V AC VOLTAGE RATING; 125 V DC VOLTAGE RATING; RIGHT POLE MOUNTING LOCATION; FIELD...

    Family: K1200 Line
  • TKMASTA12L

    TKMASTA12L

    REMOTE TYPE; TB6/TB8/TBC6/TBC8/THKM/TKC/TKM SERIES CIRCUIT BREAKER USED ON; 50/60 HZ FREQUENCY RATING; 120/240 V AC VOLTAGE RATING; 125 V DC VOLTAGE RATING; LEFT POLE MOUNTING LOCATION; FIELD...

    Family: K1200 Line
  • TKMAAS2AB3

    TKMAAS2AB3

    TKM/THKM/TKC/TB6/TB8/TBC6/TBC8 SERIES MOLDED CASE CIRCUIT BREAKER USED ON; (3) SPDT CONTACT CONFIGURATION; 240 V AC VOLTAGE RATING; 250 V DC VOLTAGE RATING; CURRENT RATING 6 AMPERE AT 240 VAC, 1/2...

    Family: K1200 Line
  • TKMA836T700

    TKMA836T700

    INTERCHANGEABLE, THERMAL MAGNETIC TYPE; 700 AMPERE CURRENT RATING; 3 POLE(S); K FRAME TYPE; INSTANTANEOUS ADJUSTMENT; TKMA MODEL

    Trip Functions: LI
    Poles: 3
    Voltage: 600
    Family: K1200 Line
  • TKMA836T450

    TKMA836T450

    INTERCHANGEABLE, THERMAL MAGNETIC TYPE; UL APPROVAL; 450 AMPERE CURRENT RATING; 3 POLE(S); K FRAME TYPE; INSTANTANEOUS ADJUSTMENT; TKMA MODEL

    Trip Functions: LI
    Poles: 3
    Voltage: 600
    Family: K1200 Line
  • TKMA836T400

    TKMA836T400

    INTERCHANGEABLE, THERMAL MAGNETIC TYPE; UL APPROVAL; 400 AMPERE CURRENT RATING; 3 POLE(S); TKM FRAME TYPE; INSTANTANEOUS ADJUSTMENT; VOLTAGE RATING 600 V; TKMA MODEL

    Trip Functions: LI
    Poles: 3
    Voltage: 600
    Family: K1200 Line
  • TKMA3T0800

    TKMA3T0800

    INTERCHANGEABLE, THERMAL MAGNETIC TYPE; UL APPROVAL; 800 AMPERE CURRENT RATING; 3 POLE(S); K FRAME TYPE; INSTANTANEOUS ADJUSTMENT; TKMA MODEL

    Trip Functions: LI
    Poles: 3
    Voltage: 600
    Family: K1200 Line
  • TJKSTA8L

    TJKSTA8L

    REMOTE TYPE; TJC/TJD/TJJ/TJK/THJK SERIES CIRCUIT BREAKER USED ON; 24 V DC VOLTAGE RATING; LEFT POLE MOUNTING LOCATION; FIELD INSTALLED; TJKSTA MODEL

    Family: TJ