Accessories and Parts

  • B220LIR

    B220LIR

    UL, CSA APPROVAL; 2000 AMPERE CURRENT RATING; INSTANTANEOUS/LONG DELAY TIME ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT

    Trip Functions: LI
    Family: MicroVersaTrip
  • B220LSHGDMR

    B220LSHGDMR

    INSULATED CASE TYPE; CSA APPROVAL; 2000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES METERING AND COMMUNICATION

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B220LSHGDPMR

    B220LSHGDPMR

    INSULATED CASE TYPE; CSA APPROVAL; 2000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES PROTECTIVE RELAY, METERING AND...

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B220LSHGDPR

    B220LSHGDPR

    INSULATED CASE TYPE; CSA APPROVAL; 2000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES PROTECTIVE RELAY AND COMMUNICATION

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B220LSHGDR

    B220LSHGDR

    CSA APPROVAL; 2000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B220LSHGDZ1MR

    B220LSHGDZ1MR

    INSULATED CASE TYPE; CSA APPROVAL; 2000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES ZONE SELECTIVE INTERLOCK, METERING AND...

    Family: MicroVersaTrip
  • B220LSHGDZ1PMR

    B220LSHGDZ1PMR

    INSULATED CASE TYPE; CSA APPROVAL; 2000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES ZONE SELECTIVE INTERLOCK, PROTECTIVE...

    Family: MicroVersaTrip
  • B220LSHGDZ1PR

    B220LSHGDZ1PR

    INSULATED CASE TYPE; CSA APPROVAL; 2000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES ZONE SELECTIVE INTERLOCK, PROTECTIVE...

    Family: MicroVersaTrip
  • B220LSHGDZ1R

    B220LSHGDZ1R

    INSULATED CASE TYPE; 2000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME ADJUSTMENT; MICROVERSATRIP PLUS[R] BRAND

    Family: MicroVersaTrip
  • B220LSHGDZ2MR

    B220LSHGDZ2MR

    INSULATED CASE TYPE; CSA APPROVAL; 2000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES SHORT TIME SELECTIVE INTERLOCK,...

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B220LSHGDZ2PMR

    B220LSHGDZ2PMR

    INSULATED CASE TYPE; CSA APPROVAL; 2000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES SHORT TIME SELECTIVE INTERLOCK,...

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B220LSHGDZ2PR

    B220LSHGDZ2PR

    INSULATED CASE TYPE; CSA APPROVAL; 2000 AMPERE CURRENT RATING; HIGH RANGE INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT DEFEATABLE ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES SHORT TIME SELECTIVE INTERLOCK,...

    Trip Functions: LSIG
    Family: MicroVersaTrip