Accessories and Parts

  • B220LSIGZ1R

    B220LSIGZ1R

    UL, CSA APPROVAL; 2000 AMPERE CURRENT RATING; INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES ZONE SELECTIVE INTERLOCK

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B220LSIGZ2MR

    B220LSIGZ2MR

    INSULATED CASE TYPE; UL, CSA APPROVAL; 2000 AMPERE CURRENT RATING; INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES SHORT TIME SELECTIVE INTERLOCK, METERING AND COMMUNICATION

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B220LSIGZ2PMR

    B220LSIGZ2PMR

    INSULATED CASE TYPE; UL, CSA APPROVAL; 2000 AMPERE CURRENT RATING; INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES SHORT TIME SELECTIVE INTERLOCK, PROTECTIVE RELAY,...

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B220LSIGZ2PR

    B220LSIGZ2PR

    INSULATED CASE TYPE; UL, CSA APPROVAL; 2000 AMPERE CURRENT RATING; INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES SHORT TIME SELECTIVE INTERLOCK, PROTECTIVE RELAY AND...

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B220LSIGZ2R

    B220LSIGZ2R

    UL, CSA APPROVAL; 2000 AMPERE CURRENT RATING; INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME, GROUND FAULT ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES SHORT TIME SELECTIVE INTERLOCK

    Trip Functions: LSIG
    Family: MicroVersaTrip
  • B220LSIMR

    B220LSIMR

    INSULATED CASE TYPE; UL, CSA APPROVAL; 2000 AMPERE CURRENT RATING; INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES METERING AND COMMUNICATION

    Trip Functions: LSI
    Family: MicroVersaTrip
  • B220LSIPMR

    B220LSIPMR

    INSULATED CASE TYPE; UL, CSA APPROVAL; 2000 AMPERE CURRENT RATING; INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES PROTECTIVE RELAY, METERING AND COMMUNICATION

    Trip Functions: LSI
    Family: MicroVersaTrip
  • B220LSIPR

    B220LSIPR

    INSULATED CASE TYPE; UL, CSA APPROVAL; 2000 AMPERE CURRENT RATING; INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT; INCLUDES PROTECTIVE RELAY AND COMMUNICATION

    Trip Functions: LSI
    Family: MicroVersaTrip
  • B220LSIR

    B220LSIR

    UL, CSA APPROVAL; 2000 AMPERE CURRENT RATING; INSTANTANEOUS/LONG DELAY TIME/SHORT DELAY TIME ADJUSTMENT; MICROVERSATRIP[R] BRAND; REPLACEMENT TRIP UNIT

    Trip Functions: LSI
    Family: MicroVersaTrip
  • B440LSI B440LSI, front

    B440LSI

    General Electric B440LSI, MicroVersaTrip, Trip Unit, Used On Power Break II Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Instantaneous

    Amperage: 4000
    Trip Functions: LSI
    Family: MicroVersaTrip
  • B440LSIG B440LSIG, front

    B440LSIG

    General Electric B440LSIG, MicroVersaTrip, Trip Unit, Used On Power Break II Breakers With 4000A Maximum Allowable CT, 4000A Breaker Current Sensor, Overcurrent Protection: Long-Time, Short-time, Instantaneous, Ground Fault

    Amperage: 4000
    Trip Functions: LSIG
    Family: MicroVersaTrip
  • BPGF100K BPGF100K

    BPGF100K

    The BPGF100K replaces the GC200E relay used in QED Switchboards with Bolted Pressure switches. Pick up range 60-1200A when used with GT-1327 and GT-1330 Ground Fault sensors. CT Ratios supported are 600:1 (default) and 1000:1. Values are read from the...

    Amperage: 1200
    Family: Bolt Loc